TOP

實驗室認証

TAF認証

Realized the necessity of accredited laboratory and participated in CNLA (former TAF) program. CHAOLI gained certification on December 15th, 2003 Wind & Rain Testing Laboratory.

 

 

Our company has gotten accredited testing laboratory by Chinese National Laboratory Accreditation(CNLA).

 

 

 

Our laboratory provides service for testing items:
 

  • Wind & Rain Test- Water Penetration, Air Infiltration, Wind Resistance...etc.

  • PSD Testing - Air Permeability Test, Crowd Load Deflection , Train Wind Pressure, Combined Load Deflection

 

  • Fire Resistance Test

Download or fill out application form according to your need. If you apply for the test for the first time, we suggest  downloading the form which contains a complete  testing application manual.  On the other hand, if you have applied for test before, you are likely to fill out the form to speed up the applying process.

 

《Please notice before you click》
When you choose download application form, click the link below and use the right-click and then select “save as” which will save your valuable time.
 

Testing Items Download 

Wind &Rain test for

Doors, windows, curtain walls
CLICK HERE
other  testings CLICK HERE

Testing Laboratory Profile

CHAOLI TECHNOLOGY CORP. TEST LABORATORY has already been accredited:
 

Accredited code:

 

1011

Testing  Field: Constructional test
Accredited Items: LA2202 Test for deformation under wind pressure of building curtain walls, LA2203 Test for water penetration performamce of building curtain walls,LA2301 Test for wind resistance of windows and doors, LA2303 Test for watertightness of windows and doorsets under dynamic pressure.
Testing Items: Curtain walls, doors &windows testing methods:CNS13972、A3367 ,CNS13974、A3369 , CNS11526、A3235 , CNS11528、A3237

 

 

Items are accredited by CNLA:

 

1. Fire resistant wall Test

2. Fire rated door Test

3. Wind& Rain Test(wind resistance, water penetration)

 

Furthermore, we are preparing for following items testing

 

1、Testing for PVC, ABS, FRP and other types of tubing

 

2、Testing for Ceramic Tile 

 

3、Testing for Bulletproof

 

4、Other testing regarding stress, strain, temperature and thermo

 

5、Other testing as requested

 

 

Our laboratory endeavors to provide tests for disaster prevention of constructional material. 

TEST   ITEM

Standard

Test range note

L545 Dimension

Windows and Doors

CNS 3092 Sec. 7

CNS 6400 Sec. 7

CNS 7184 Sec. 7

CNS 7477 Sec. 7

CNS 12430 Sec. 7

On-site testing included

 

 

L760 Air Permeability

Windows and Doorsets

CNS 11527

  Air leakage:

  0.1 ~ 500 m^3/h

 

L762 Water Penetration Performance

Windows and Doorsets

CNS 11528

  Water spraying:

  0.1 ~ 600 L/min

 

L764 Wind Resistance

Windows and Doors

CNS 11526

  Pressure:1 ~ 20000 Pa

  Flexure:0.1 ~ 200 mm

 

L765 Test for Edge Member Strength

Windows and Doors

CNS 3092 Sec. 9.7

CNS 6400 Sec. 9.7

CNS 7184 Sec. 9.9

CNS 7477 Sec. 9.9

CNS 12430 Sec. 9.5

On-site testing included

  Flexure:0.1 ~ 100 mm

 

L769 Test for Opening Force

Windows and Doors

CNS 3092 Sec. 9.6

CNS 6400 Sec. 9.6

CNS 7184 Sec. 9.7

CNS 7477 Sec. 9.7

CNS 12430 Sec. 9.4

On-site testing included

  Standard Weight:5 kg

 

L999 Coating / Film Thickness

Windows and Doorsets

CNS 8406-2

CNS 15200-1-7 Sec.5.5.7

On-site testing included

  Thickness:11.4 ~ 992 um  

L560 Test for Durability to Impact

Steel Doors, Aluminum Doors

CNS 7184 Sec. 9.8

CNS 7477 Sec. 9.8

  Bag mass:30 kg  

L760 Field Air Infiltration Test

Doors、Windows、Curtain Wall

AAMA 502 ( Exclude Sec. 4 )

AAMA 503 ( Exclude Sec. 5 )

ASTM E783 ( Exclude Sec. 9.1 )

  Air leakage:

  0.0003 ~ 0.0770 m^3/sec

 

L760 Air Leakage Under Specified

Pressure Differences

Curtain Wall

ASTM E283

  Air leakage:

  0.03 ~ 138.89 L/sec

  Test body height

  13 m

L760 Air Permeability Performance

Curtain Wall

CNS 13971

  Air leakage:

  0.1 ~ 500 m^3/h

  Test body height:

  13 m

L761 Structural Performance by Uniform Static Air Pressure Difference

Curtain Wall

ASTM E330

  Pressure:1 ~ 20000 Pa

  Flexure:0.1 ~ 200 mm

  Test body height:

  13 m

L761 Deformation Under Wind Pressure

Curtain Wall

CNS 13972

  Pressure:1 ~ 20000 Pa

  Flexure:0.1 ~ 200 mm

  Test body height:

  13 m

L762 Water Penertration by Rapid Pulsed Air Pressure Difference

Curtain Wall

ASTM E331

ASTM E547

ASTM E2268

  Water spraying:

  0.1 ~ 600 L/min

  Test body height:

  13 m

L762 Water Penertration Performance

Curtain Wall

CNS 13974

  Water spraying:

  0.1 ~ 600 L/min

  Test body height:

  13 m

L762 Water Penertration Performance

( Dynamic Pressure )

Doors、Windows、Curtain Wall

AAMA 501.1

  Water spraying:

  0.1 ~ 600 L/min

  Test body height:

  13 m

L762 Field Water Penertration Performance

Doors、Windows、Curtain Wall

AAMA 501.2

( Exclude Sec. 6.5 )

AAMA 502

( Exclude Sec. 4 )

AAMA 503

( Exclude Sec. 5 )

ASTM E1105

  Water spraying:( ASTM )

  0 ~ 30 L/min

  Water spraying:( AAMA )

  30 ~ 35 psi

 

L762 Water Penertration Performance

( Dynamic Pressure )

Doors、Windows、Curtain Wall

CNS 13973

  Water spraying:

  0.1 ~ 600 L/min

  Test body height:

  13 m

L763 Displacements Associated

with Seismic Movements and

Building Sway

Doors、Windows、Curtain Wall

CNS 14281

  Displacement:

  -120 ~ 120 mm

  Test body height:

  13 m

L763 Displacements Associated 

with Seismic Movements and 

Building Sway

Curtain Wall and Subjected

AAMA 501.4

  Displacement:

  -120 ~ 120 mm

  Test body height:

  13 m

L763 Vertical Inter-Story Movements

Windows、Window Wall、Curtain Wall and Storefront System

AAMA 501.7

  Displacement:

  -20 ~ 20 mm

  Test body height:

  13 m

L768 Sliding Test

Sheaves for Sliding Doors and Windows

CNS 12431 Sec. 7.1.1

  record of cycles:

  0 ~ 999999 times

  Dim max:

  W:3.0m x H:2.5 m